SPECIFICATIONS:
• Architectural design and precision engineering combine to produce a bold appearance and superior performance.
• Heavy-duty vandal resistant luminaire for use in public areas that are subject to high levels of abuse and vandalism. Mois- ture resistant for indirect weather and liquid spray. UL damp location listed.
• Extruded aluminum housing, die-cast aluminum end caps, and an unbreakable polycarbonate diffuser are the outer components which protect the luminaire.
• Applications: Schools, public housing complexes, and parking garages. Use in hospitals, police precincts, recreation facilities, and all medium to maximum-security locations.
• Modules: Luminaire lengths of 2Ft and 4Ft. One, two, or three-lamp cross sections.
• T5 Lamps: 14W-T5 or 24W-HO-T5 2Ft. lamps, 28W-T5 or 54W-HO-T5 4Ft. lamps.
• T8 Lamps: 17W-T8 2Ft. lamps, 32W-T8 4Ft. lamps. Other T8 lamps on request.
• Diffusers:Fabricatedfromunbreakablewhitepolycarbonate plastic material in a .156” thickness. Inside linear rib prisms for optimal light control. Smooth outside surface resists dirt accumulation and cleans easily.
• Tamperproo ng:EachdiffuserissecuredbyfourTorx-Head stainless steel screws along the sides of the diffuser and by the overlapping end caps.
M5000 SERIES
Architectural Vandal Resistant Luminaire UL Damp Location Listed
Fixture Type: Job Information:
• Housings: Heavy-duty extruded aluminum housing. Die-cast aluminum end caps. Die formed cold rolled steel internal re-  ector/wire way cover. All  nished with a matte white polyester powder coating that produces a re ectivity of 90% or greater. Housing and end caps are fully gasketed along edges that meet with diffuser.
• Ballasts T5: Electronic programmed start, normal light output, high power factor, THD less than 10%. Up to 2-lamps per 24W-HO-T5 or 28W-T5 ballast. Up to 3-lamps per 14W-T5 or 54W-HO-T5 ballast. Most ballast/lamp combinations have zero degree F low temperature starting. When critical specify low temp.
• Ballasts T8: Electronic instant start, high power factor, THD less that 10%. Optional programmed rapid start. Low ballast factor (.78bf), normal ballast factor (.88bf), or high ballast factor (1.20bf) as specified. Up to 3-lamps per ballast is standard. Most ballast/lamp combinations have zero degree F low temperature starting. When critical specify low temp.
• Voltage:Multi-voltoperatesarangefrom120V-277V,50HZ-60HZ.
• Emergency battery backup: Integrated packs range from 500 up to 2000 lumen output. Varies with lamp type.
• Installations: Mount individually or continuously. Housing has back knockouts and mounting holes. End caps have internal knockouts which are not visible on the outside, for surface con- duit entry or for continuous mounting.
• UL and CUL listed 1598 and bears a UL damp location label. Union made and labeled.