SPECIFICATIONS:
• The HB80  uorescent high bay luminaire offers an alternative to the traditional HID high bay source and is now becoming the preferred method for high mounting height applications. Linear T8 lamp and ballast technologies, advanced optics and ultra-high re ective materials, are built into a full hous- ing luminaire design.
• Designed for warehouses, manufacturing facilities, big-box retail environments, and school gymnasiums that have high ceilings and wide open spaces. Use in new installations or as a direct replacement for older inef cient HID luminaires.
• Provides a high lumen energy saving package with the reli- ability and bene ts of a  uorescent source and none of the disadvantages of an HID source.
• Ultra high ef ciency: Over 98%, industrial style luminaire delivers up to 3540 initial lumens per each 32W-T8-82 CRI “800” series lamp when used with a 1.2 ballast factor high- light output ballast. Specify 2-, 3-, 4-, 5-, or 6-lamps.
• Energy consumption: A 6-lamp luminaire using two 3-lamp high-light output ballasts consumes about one-half the energy of a typical 400W metal halide high bay  xture while maintaining comparable light levels. Replaces an HID high bay on a one-to-one basis with dramatic energy savings.
• Lamp and ballast technology features: Up to 30,000-hour lamp life, highest energy savings, zero degree F starting temps, instant on/instant re-strike, sound rating a quiet “A”, 93% lumen maintenance, 3000K, 3500K, and 4100K color temperatures, 82 CRI.
• Re ector: Luminaire design features a precision-formed multi-beveled Miro-4 enhanced aluminum re ector with a re ectivity of 95%. CAD designed to the corresponding num- ber of lamps for maximum optics and performance. Other materials on request.
• Ballasts T8: Electronic instant start, high power factor, THD less than 10%. Low ballast factor (.78bf), normal ballast factor (.88bf), or high ballast factor (1.20bf) as speci ed. Up to 4-lamps per ballast is standard. Six-lamp luminaires to have one 4-lamp and one 2-lamp combination as standard or optional two 3-lamp ballasts. Optional T8 ballast: programmed rapid start.
• Voltage: Multi-volt operating a range of 120V-277V, 50HZ-60HZ is standard. 480V/60HZ is available. Multi-circuit wiring upon request.
• Emergency battery back up: Integrated packs range from 500 lumens up to 2000 lumens. Varies with lamp type.
• Housings: Die formed code gauge cold rolled steel permanently assembled with rivets and screws. Vented top for optimum ballast performance. Ample knockouts are provided. Quick wiring access plate provided. White enamel  nish on all parts. Post painted powder coated on request. An all-aluminum housing is optional
• Sockets: Bi-pin rotary locking type. Constructed from UV and heat resistant breakage-free polycarbonate.
• Occupancy sensors: Self-contained sensor mounts directly to luminaire. Provides occupancy control to individual luminaire with passive infrared technology. Reliable coverage up to 40Ft. height. Interchangeable lenses for 360 degree or aisle way pattern.
• Optional accessories: Ship separately; Wireguards, V hangers, stem sets, cable sets. Pre-installed; Y-shaped cable/paddle hangers and single stem mounting box. Wired-in; GLR or GMF fusing, 120V 18/3-SJT cord sets, 120V 16/3-SJT cord and NEMA L5-15P twist-lock plug set, 277V 16/3-SJT cord and NEMA L7-15P twist-lock plug set,  ex sets.
• ULandCULlisted1598andbearstheirlabel.Suitablefordry locations or optional damp locations with UL Damp Label. Union made and labeled.