Page 203 - Mercury Lighting | Fluorescent Catalog
P. 203

ORDERING DATA: Fill in boxes below with corresponding bold options. Example: M450-228-T5-ADR-ELBD-20-UNI-EMPK/I32
Series
M450
Lumascence Series.
No. of Lamps Cross
2
Lamps
Lamp Wattage/ Ea./Nominal Fixture Length
14
14W-T5/24"
24
24W-HO-T5/24" *Systems #3 & #4 Only.
28
28W-T5/48"
54
54W-HO-T5/48" *Systems #3 & #4 Only.
Detail
Lamp Type
T5
Linear T5
HO-T5
Linear HO-T5
Optional Diffuser
ADR
Hi Impact Clear Acrylic/50% DR. Internal Linear Prisms.
ADR100
Hi Impact Clear Acrylic/100% DR. Internal Linear Prisms.
Operating System/ Stand-By Power Voltage Ballast Type
ELBD 20 UNI System #1. One 2-Lamp 20% Stand-By/ Universal
T5 0-10V Electronic System #1. Factory Voltage, Dimming Ballast, Set, Field Reset. Multi-Volt Programmed Start. 120V-277V, FS-505 Sensor or equal. 40 50HZ-60HZ, Stand-By Level Power 40% Stand-By/ <10%THD. Board Factory Set to System #1. Factory
Emergency Battery Back Up*
Leave Blank No EMPK Required.
EMPK/I32
I-32 or Equal 500 Lumens. One 28W-T5 Lamp.
EMPK/ISL28
ISL-28 or Equal 500 Lumens. One T5 Lamp.
EMPK/I320
I-320 or Equal 1050 Lumens. One T5 or HO-T5 Lamp.
EMPK/____
Emergency Pack As Speci ed.
It has been reported from the  eld that certain brand T5 and HO-T5 lamps
do not operate properly in  xtures with emergency battery backup. Please inquire from factory for the most up-to-date list of acceptable lamps when using emergency backup options.
Misc.
TP
Two Tamper-Proof Screws Per End. Vandal-Proo ng Component.
DL
UL Damp Labeled.
Order Separately
TPT
Tamperproof Screwdriver
Sensor
System #3. One 1-Lamp 0
T5 or HO-T5 Electronic 0% Stand-By/ Programmed Start System #4. Ballast, Wired to
Sensor. One 1-Lamp
T5 or HO-T5 Electronic
Programmed Start
Ballast. FS-505 Sensor
or Equal. Stand-By
Level 50% Only.
2Ft. Unit
Stairwell Location
SPECIFICATIONS SUBJECT TO CHANGE, CONSULT FACTORY WHEN CRITICAL.
STAIRWELL 203
Dim at 20, 40, or 60% Set, Field Reset. Level. Can Be Reset in
Field. 14W-T5 or 28W- 60
T5 Lamps Only. 60% Stand-By/ ELBD5 System #1. Factory
System #2. One 2-Lamp Set, Field Reset. T5 0-10V Electronic 5
Dimming Ballast, 5% Stand-By/ Programmed Start. System #2. FS-505 Sensor or equal. 50
Dims to 5% Stand-By
Level Only. 14W-T5 or 50% Stand-By/ 28W-T5 Lamps Only. System #3.
ELBS
System #4. One 2-Lamp T5 or HO-T5 Electronic Programmed Start Ballast, Wired to Sensor. FS-505 Sensor or Equal. Stand-By Level is "Off Mode".
DIMENSIONAL DATA
3.5"
ELB2
*
7.25"
M450-T5 FLUORESCENT
DOWNLOAD SHEET