Page 336 - Mercury Lighting | Fluorescent Catalog
P. 336

Fixture Type: Job Information:
MP19 SERIES
Linear T8 Fluorescent Shallow Under Cabinet, Task Luminaire
SPECIFICATIONS:
• An architecturally pleasing linear T8  uorescent luminaire designed for all under cabinet and task lighting needs. Luminaire usually mounts out-of-sight, offering high performance task illumination. Solid front design keeps extraneous light from hitting the eyes. Improves productivity, reduces fatigue and eyestrain, and adds a sense of well being to persons doing task work.
• Applications: Task lighting of desks and workstations in of-  ce, educational, and hospital environments. Can be incor- porated into modular furniture. Use as under cabinet lighting in residential and multi-family kitchens.
• One-lamp cross section, T8 linear  uorescent.
• Length/Lamps: 2FT/17W-T8, 3FT/25W-T8, 4FT/32W-T8. On request, 1.5FT/15W-T8 or T12.
• Housings: Die formed housing, ends, and front panel from code grade cold rolled steel as one continuous seamless piece. Removable bottom panel provides access to the ballast and wiring. Ample knockouts are provided. Finished with a high quality white enamel paint offering an 87% re ectivity. Optional  nishes on request.
• Diffusers: A one-piece clear diffuser with sharp linear prisms is extruded from 100% virgin acrylic material for high performance, durability, and long lasting service. Permits maximum light transmission while controlling direction and glare. Snaps into place and is easily removed for lamp access.
Grounded Outlet Optional Rocker Switch Optional
• Ballasts T8: Electronic instant start, normal light output, high- power factor, THD less that 10%. Optional T8 performances: rapid start circuit, high light output, low-watt. Lutron or Ad- vance dimming ballasts as speci ed.
• Voltage:Multi-voltoperatesarangefrom120V-277V,50HZ-60HZ.
• Switching & Electrical Options: All options 120V only. Rocker switch, rotary switch, grounded 3-wire outlet, SJT 18/3-cord and plug power feed.
• Emergency battery back up: Integrated pack for 500-Lumen output. Others upon request.
• Installations: Suitable for individual mounting under shelving and cabinets. May be butted for end-to-end continuous use with another unit. Keyhole slots and mounting holes are provided along the top for installations.
• UL and CUL listed 1598 and bears their label. Suitable for dry locations or optional damp locations with UL Damp Label. Union made and labeled.
336 MERCURY LIGHTING FLUORESCENT
12/11