SPECIFICATIONS:
• High ef ciency recessed T5  uorescent total volume luminaire featuring an ultra-shallow design and custom formulated frosted acrylic light shield. With a depth of less than two inches virtually  ts into any plenum space. Frosted light shield al- lows maximum direct-light transmission which delivers higher  xture ef ciencies. Re ector system enables precise indirect light distribution.
• Fixture ef ciencies exceed 71% (as tested with two 28W-T5 lamps) with this computer designed precision optical system. May qualify for state and national rebate programs.
• The system delivers comfortable illumination by  lling the entire volume of space evenly. Broad angle illumination lights walls and vertical surfaces creating a more open and com- fortable space. All components are recessed above the ceiling line. Install in ceilings as low as eight feet.
• Center light shield: Extruded with internal linear ribs from 100% acrylic with an added colorless frosting blended into the material. Hides all lamp imaging. Light shield snaps in and out for lamp access. Optional perforated steel shield slides over existing acrylic shield when this style is desired.
• Housing: Die formed from code-grade heavy gauge cold rolled steel and fabricated in a computer-controlled operation. Housing back forms the indirect re ector. Center ballast and wiring cover is removable from below. Rivets and self-locking joints hold all parts together for strength and unity. Pry-out style grid supports are located on the ends.
Detail
80 MERCURY LIGHTING FLUORESCENT
ZENITH HE ZR1 SERIES
Ultra Shallow 1-13/16” 1X4 Indirect/Direct Luminaire Center Frosted Acrylic Light Shield
Fixture Type: Job Information:
• Finish: A custom formulated non-glare white powder coating is applied to the re ectors and the housing after fabrication. Provides a re ectivity of at least 90%.
• T5 Lamps: Two 4Ft. linear  uorescent lamps; 28W-T5 or 54W-HO-T5.
• Ballasts T5: Electronic programmed start, normal light output, high power factor, THD less than 10%. Lutron or Advance dim- ming ballasts as speci ed.
• Voltage: Multi-volt operates a range from 120V-277V, 50HZ-60HZ. Dedicated voltages on request.
• Emergency battery back up: Mounted externally on top of the housing with mini wire cover. Adds approximately 1-5/32” ad- ditional depth to the luminaire. Integrated packs range from 500 up to 825 lumen output. Varies with lamp type.
• Installations: Designed for installation into NEMA Type G lay-in acoustical grid ceiling systems, 1” grid or 9/16”  ne-line grid. Four pullout type security clips, located in the housing, lock over the ceiling grid work. Four auxiliary suspension points are also provided for securing to building structure. A quick wiring access plate is located on back of the housing. Factory installed lamps and power whips as speci ed.
• UL and CUL listed 1598 and bears their label. Suitable for dry locations or optional damp locations with UL Damp Label. Union made and labeled.
08/13