Page 91 - Mercury Lighting | Fluorescent Catalog
P. 91

ORDERING DATA: Fill in boxes below with corresponding bold options. Example: ZT3-14G-254-HO-T5-ELB-UNI-EMPK/I320-FLX-LP835
Series
ZT3
Zenith HE Fully Luminous Panel
FK-14
Module Size/Ceiling
No.of Lamps/ Wattage Ea. Lamp
228
2-28W-T5 or 2-28W-T8 Linear
328
3-28W-T5 or 3-28W-T8 Linear
254
2-54W-HO-T5 Linear
354
3-54W-HO-T5 Linear
232
2-32W-T8 Linear
332
3-32W-T8 Linear
__
As Speci ed.
Lamp Type
T5
Linear T5
HO-T5
Linear High Output T5
OCT
Linear T8
Ballast Type
ELB
T5 or HO-T5 Electronic Programmed Start.
Up to 2-Lamps/ 28W-T5 Ballast.
Up to 3-Lamps/ 54W-HO-T5 Ballast.
ELB
T8 Electronic Instant Start. Normal
Ballast Factor (.88bf). Up to 3-Lamps/32W-T8 or 28W-T8 Ballast.
ELBL
T8 Electronic
Instant Start. Low Ballast Factor (.78bf). Up to 3-Lamps/32W-T8 or 28W-T8 Ballast.
ELBH
T8 Electronic Instant Start. High Ballast Factor (1.20bf).
Up to 3-Lamps/32W-T8 or 28W-T8 Ballast.
ELBS
T8 Electronic Programmed
Rapid Start.
Normal Ballast
Factor (.88bf).
Up to 3-Lamps/ 32W-T8 or 28W-T8 Ballast.
ELBSL
T8 Electronic Programmed Rapid Start.
Low Ballast
Factor (.78bf).
Up to 3-Lamps/ 32W-T8 or 28W-T8 Ballast.
ELBSH
T8 Electronic Programmed Rapid Start. High Ballast Factor (1.20bf).
Up to 3-Lamps/32W-T8 or 28W-T8 Ballast.
ELBD-SD
T8 Electronic Programmed Rapid Start. Bi-Level Step Dimmer.
Up to 2-Lamps/32W-T8 Ballast.
ELBD
T8 Electronic Dimming. Lutron or Advance as Speci ed.
ELB-____
T8 Electronic As Speci ed.
Voltage
UNI
Universal Voltage. Multi-Volt 120V-277V, 50HZ-60HZ.
120V
Dedicated Voltage 120V-60HZ.
277V
Dedicated Voltage 277V-60HZ.
Misc
EMPK/I32
I-32 or Equal 500 Lumens. One 28W-T5 or 32W-T8 Lamp.
EMPK/I48
I-48 or Equal 700 Lumens. One or Two 32W-T8 Lamps.
EMPK/I320
I-320 or Equal 1350 Lumens. One 28W-T5 or 54W-HO-T5 Lamp. One or Two 32W-T8 Lamps.
EMPK/I232
I-232 or Equal 1400 Lumens. Two 32W-T8 Lamps.
EMPK/ISL28
ISL-28 or Equal 500 Lumens. One 28W-T5 Lamp.
EMPK/ISL54
ISL-54 or Equal 825 Lumens. One 28W-T5 or 54W-HO-T5 Lamp.
EMPK/ISL540
ISL-540 or Equal 1300 Lumens. One 28W-T5 or 54W-HO-T5 Lamp.
FLX
6Ft. Single Circuit Power Flex. (Specify Voltage).
FLX2
6Ft. 2-Circuit Power Flex. (Specify Voltage).
2B
2-Ballasts, 2-Circuits.
DL
UL Damp Label.
L___
Factory Lamps Installed, Specify Color. Ex: L741
1x4 Flange Kit/ For NEMA Type F Applications. Order Separately. For Dry Wall Installations. Use with "G" Type Fixture.
PHOTOMETRICS:
Available upon request.
CROSS SECTIONS:
14G
1X4 Module/ NEMA Type G/ Lay-in Grid , 1" or 9/16" Fine Line.
1-, 2- or 3-lamps, T5 or T8
4.5" 11.75"
3.5"
SPECIFICATIONS SUBJECT TO CHANGE, CONSULT FACTORY WHEN CRITICAL.
ARCHITECTURAL - RECESSED 91